MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
Results of the water heating using steam calculation. More...
#include <water_heating_using_steam.h>
Public Attributes | |
| double | temp_water_out = 0 |
| Outlet water temperature \([\unit{K}]\). | |
| double | bp_temp_water_out = 0 |
| Boiling point temp of water out \([\unit{K}]\). | |
| bool | bp_temp_warning_flag = false |
| Warning if outlet water at/above boiling point. | |
| double | flow_bypass_steam = 0 |
| Bypass steam flow \([\unit{kg/hr}]\). | |
| double | enthalpy_steam_in = 0 |
| Inlet steam enthalpy \([\unit{kJ/kg}]\). | |
| double | enthalpy_steam_out = 0 |
| Outlet steam enthalpy \([\unit{kJ/kg}]\). | |
| double | enthalpy_makeup_water = 0 |
| Makeup water enthalpy \([\unit{kJ/kg}]\). | |
| double | energy_saved_dwh = 0 |
| Energy saved in DWH \([\unit{kJ/yr}]\). | |
| double | energy_saved_boiler = 0 |
| Energy saved in boiler \([\unit{kJ/yr}]\). | |
| double | water_saved = 0 |
| Water saved \([\unit{m3/yr}]\). | |
| double | heat_gain_rate = 0 |
| Heat gain rate \([\unit{kJ/hr}]\). | |
Contains all output values from the water heating using steam calculation.
Definition at line 22 of file water_heating_using_steam.h.
| bool water_heating_using_steam::WaterHeatingUsingSteamResults::bp_temp_warning_flag = false |
Definition at line 25 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::bp_temp_water_out = 0 |
Definition at line 24 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::energy_saved_boiler = 0 |
Definition at line 31 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::energy_saved_dwh = 0 |
Definition at line 30 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::enthalpy_makeup_water = 0 |
Definition at line 29 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::enthalpy_steam_in = 0 |
Definition at line 27 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::enthalpy_steam_out = 0 |
Definition at line 28 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::flow_bypass_steam = 0 |
Definition at line 26 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::heat_gain_rate = 0 |
Definition at line 33 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::temp_water_out = 0 |
Definition at line 23 of file water_heating_using_steam.h.
| double water_heating_using_steam::WaterHeatingUsingSteamResults::water_saved = 0 |
Definition at line 32 of file water_heating_using_steam.h.