MEASUR-Tools-Suite v1.2.6
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
Inputs for the annual dryer operating-cost calculation. More...
#include <dryer_operating_cost.h>
Public Attributes | |
| DryerType | dryer_type |
| Dryer configuration to evaluate. | |
| double | flow_rate |
| Inlet airflow \([\unit{\scfm}]\). | |
| double | pressure |
| Inlet gauge pressure \([\unit{psig}]\). | |
| double | temperature |
| Inlet temperature \([\unit{\degreeFahrenheit}]\). | |
| double | annual_operating_hours |
| Annual dryer operating time \([\unit{\hour\per\year}]\). | |
| double | cost_of_electricity |
| Electricity rate \([\unit{\dollar\per\kilowatt\hour}]\). | |
| double | cost_of_compressed_air |
| Compressed-air rate in dollars per 1,000 standard cubic feet. | |
| double | cost_of_cooling_water |
| Cooling-water rate in dollars per 1,000 gallons. | |
| double | heater_power |
| Manual heater load \([\unit{\kilowatt}]\); zero selects automatic sizing. | |
| double | heating_hours_per_day |
| Heater operating time per 24 hours \([\unit{\hour}]\). | |
| double | purge_rate |
| Purge airflow as dryer-capacity percentage points \([\unit{\percent}]\). | |
| double | purge_flow_rate |
| Direct purge airflow \([\unit{\scfm}]\). | |
| double | design_ddc_percentage |
| Design desiccant capacity percentage points \([\unit{\percent}]\). | |
| double | regeneration_cycle_length |
| Regeneration half-cycle length \([\unit{\hour}]\). | |
| double | motor_power |
| Manual motor size \([\unit{\horsepower}]\); zero selects automatic sizing. | |
| PurgeInputMode | purge_input_mode |
| Active purge input representation. | |
Definition at line 38 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::annual_operating_hours |
Definition at line 43 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::cost_of_compressed_air |
Definition at line 45 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::cost_of_cooling_water |
Definition at line 46 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::cost_of_electricity |
Definition at line 44 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::design_ddc_percentage |
Definition at line 51 of file dryer_operating_cost.h.
| DryerType dryer_operating_cost::Input::dryer_type |
Definition at line 39 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::flow_rate |
Definition at line 40 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::heater_power |
Definition at line 47 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::heating_hours_per_day |
Definition at line 48 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::motor_power |
Definition at line 53 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::pressure |
Definition at line 41 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::purge_flow_rate |
Definition at line 50 of file dryer_operating_cost.h.
| PurgeInputMode dryer_operating_cost::Input::purge_input_mode |
Definition at line 54 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::purge_rate |
Definition at line 49 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::regeneration_cycle_length |
Definition at line 52 of file dryer_operating_cost.h.
| double dryer_operating_cost::Input::temperature |