o2_enrichment.h
1#pragma once
7namespace o2_enrichment {
8
33
50 double o2_comb_air,
51 double o2_comb_air_enriched,
52 double flue_gas_temp,
53 double flue_gas_temp_enriched,
54 double o2_flue_gas,
55 double o2_flue_gas_enriched,
56 double comb_air_temp,
57 double comb_air_temp_enriched,
58 double fuel_consumption
59);
60
66double calculateHeatInput(double flue_gas_temp);
67
73double calculateAirSpecificHeat(double comb_air_temp);
74
82double calculateAirCorrection(double air_specific_heat, double flue_gas_temp, double excess_air);
83
91double calculateCombustionAirCorrection(double air_specific_heat, double comb_air_temp, double excess_air);
92
100double calculateStdAvailableHeat(double heat_input, double air_correction, double combustion_air_correction);
101
109double calculateAvailableHeat(double o2_comb_air, double flue_gas_temp, double available_heat);
110
111} // namespace o2_enrichment
112
O2 enrichment calculations for fuel-fired furnaces.
double calculateStdAvailableHeat(double heat_input, double air_correction, double combustion_air_correction)
Calculates standard available heat.
double calculateAirSpecificHeat(double comb_air_temp)
Calculates air specific heat from combustion air temperature.
double calculateHeatInput(double flue_gas_temp)
Calculates heat input from flue gas temperature.
O2EnrichmentResults calculateO2Enrichment(double o2_comb_air, double o2_comb_air_enriched, double flue_gas_temp, double flue_gas_temp_enriched, double o2_flue_gas, double o2_flue_gas_enriched, double comb_air_temp, double comb_air_temp_enriched, double fuel_consumption)
Calculates the O2 enrichment results for a fuel-fired furnace.
double calculateAvailableHeat(double o2_comb_air, double flue_gas_temp, double available_heat)
Calculates available heat.
double calculateAirCorrection(double air_specific_heat, double flue_gas_temp, double excess_air)
Calculates air correction.
double calculateCombustionAirCorrection(double air_specific_heat, double comb_air_temp, double excess_air)
Calculates combustion air correction.
Results of the O2 enrichment calculation.
double air_correction
Air correction .
double heat_input_enriched
Heat input with O2 enrichment .
double std_available_heat
Standard available heat (fraction)
double enriched_air_specific_heat
Enriched air specific heat .
double excess_air_enriched
Excess air with O2 enrichment (fraction)
double available_heat
Available heat (fraction)
double fuel_savings_enriched
Fuel savings with O2 enrichment .
double excess_air
Excess air (fraction)
double fuel_consumption_enriched
Fuel consumption with O2 enrichment .
double enriched_air_correction
Enriched air correction .
double available_heat_enriched
Available heat with O2 enrichment (fraction)
double air_specific_heat
Air specific heat .
double std_available_heat_enriched
Standard available heat with O2 enrichment (fraction)
double combustion_air_correction
Combustion air correction .
double combustion_air_correction_enriched
Combustion air correction with O2 enrichment .