MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
\begin{equation}\label{eq:opening-total-heat-loss} Q_\text{open} = \varepsilon \sigma A (T_\text{in}^4 - T_\text{amb}^4) \cdot F \cdot \frac{t_\text{open}}{100}\end{equation}
| \(Q_\text{open}\) | Opening heat loss \([\unit{ \btu\per\hour}]\) |
| \(\varepsilon\) | Surface emissivity \([\unit{ \unitless}]\) |
| \(\sigma\) | Stefan-Boltzmann constant \([\unit{ \btu\per\hour\foot\squared\degreeRankine\tothe{4}}]\) |
| \(A\) | Opening area \([\unit{ \foot\squared}]\) |
| \(T_\text{in}\) | Inside temperature \([\unit{ \degreeRankine}]\) |
| \(T_\text{amb}\) | Ambient temperature \([\unit{ \degreeRankine}]\) |
| \(F\) | Radiative view factor \([\unit{ \unitless}]\) |
| \(t_\text{open}\) | Percent time open \([\unit{ \unitless}]\) |