MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
Loading...
Searching...
No Matches

The standard cubic feet per hour is calculated by adjusting the actual volumetric flow rate for temperature to obtain flow at standard conditions (60°F, 1 atm).

\begin{equation}\label{eq:leakage-scfh} \text{SCFH} = \text{CFH} \cdot \sqrt{\frac{520}{460 + T_{\text{leak}}}}\end{equation}

Symbols
\(\text{SCFH}\)Standard cubic feet per hour of leakage \([\unit{ \cubicFoot\per\hour}]\)
\(\text{CFH}\)Volumetric flow rate of leakage \([\unit{ \cubicFoot\per\hour}]\)
\(520\)Standard gas temperature - see physics::us::kStandardGasTemperatureR \([\unit{ \degreeRankine}]\)
\(460\)Fahrenheit to Rankine offset - see physics::conversions::kFahrenheitToRankineOffset \([\unit{ \degreeRankine}]\)
\(T_{\text{leak}}\)Temperature of leaking gases \([\unit{ \degreeFahrenheit}]\)