MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
Loading...
Searching...
No Matches
Modules | Files | Namespaces | Functions
Fixture Heat Loss Calculator

Detailed Description

This calculator is used to estimate heat losses of process heating equipment due to fixtures, trays, conveyor belts, and similar equipment that enter the furnace at lower temperatures and are heated to the furnace temperature. These fixtures absorb heat from the furnace as they are heated from their initial temperature to the final furnace temperature. The calculator computes the total heat loss based on the feed rate, specific heat of the fixture material, initial and final temperatures, and a correction factor [3]. The calculation assumes there is no melting or phase change of the fixture material involved. Relevant formulas are documented below.

Heat Loss


\begin{equation}\label{eq:fixture-heat-loss} Q = \dot{m} \cdot c_p \cdot (T_\text{final} - T_\text{initial}) \cdot f_\text{corr}\end{equation}

Symbols
\(Q\)Heat loss \([\unit{ \btu\per\hour}]\)
\(\dot{m}\)Feed rate of fixture material \([\unit{ \pound\per\hour}]\)
\(c_p\)Specific heat of fixture material \([\unit{ \btu\per\pound\degreeFahrenheit}]\)
\(T_\text{final}\)Final temperature of fixture \([\unit{ \degreeFahrenheit}]\)
\(T_\text{initial}\)Initial temperature of fixture \([\unit{ \degreeFahrenheit}]\)
\(f_\text{corr}\)Correction factor \([\unit{ \unitless}]\)

Modules

 Fixture Heat Loss Formula
 

Files

file  fixture_heat_loss.h
 

Namespaces

namespace  fixture_heat_loss
 Calculates heat losses from fixtures, trays, and conveyors in process heating equipment.
 

Functions

double fixture_heat_loss::totalHeatLoss (double specific_heat, double feed_rate, double initial_temperature, double final_temperature, double correction_factor)
 Calculates the total heat loss from fixtures, trays, or conveyors.
 

Function Documentation

◆ totalHeatLoss()

double fixture_heat_loss::totalHeatLoss ( double  specific_heat,
double  feed_rate,
double  initial_temperature,
double  final_temperature,
double  correction_factor 
)

This function computes the heat loss caused by fixtures, trays, conveyor belts, and similar equipment that enter the furnace at lower temperatures and are heated to the furnace temperature. The calculation assumes there is no melting or phase change of the fixture material involved.

Parameters
[in]specific_heatSpecific heat of fixture material \([\unit{\btu\per\pound\degreeFahrenheit}]\)
[in]feed_rateFeed rate of fixture material \([\unit{\pound\per\hour}]\)
[in]initial_temperatureInitial temperature of fixture \([\unit{\degreeFahrenheit}]\)
[in]final_temperatureFinal temperature of fixture \([\unit{\degreeFahrenheit}]\)
[in]correction_factorCorrection factor \([\unit{\unitless}]\)
Returns
Total heat loss \([\unit{\btu\per\hour}]\)
See also