MEASUR-Tools-Suite v1.2.4
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
Loading...
Searching...
No Matches
compressor_eem.h
Go to the documentation of this file.
1#pragma once
2
9namespace compressed_air::assessment::compressor_eem {
10
16
21
28
34
36 double powerSavingsKw = 0.0;
37 double energySavingsKwh = 0.0;
38 double costSavings = 0.0;
39};
40
41ReduceAirLeaksResult reduceAirLeaks(double full_load_airflow, double use_airflow, double leak_airflow,
42 double leak_reduction_fraction);
43
44ImproveEndUseEfficiencyResult improveEndUseEfficiency(double full_load_airflow, double use_airflow,
45 double reduced_average_airflow);
46
47ReduceSystemAirPressureResult reduceSystemAirPressure(double full_load_airflow, double use_airflow,
48 double full_load_pressure, double full_load_power,
49 double pressure_reduction, double altitude_pressure = 14.69,
50 double atmospheric_pressure = 14.69);
51
52AdjustCascadingSetPointResult adjustCascadingSetPoint(double full_load_airflow, double use_airflow,
53 double full_load_pressure, double full_load_power,
54 double adjusted_full_load_pressure,
55 double altitude_pressure = 14.69,
56 double atmospheric_pressure = 14.69);
57
58PressureReductionSavingResult pressureReductionSaving(double operating_hours, double cost_per_kwh,
59 double rated_full_load_power,
60 double rated_full_load_pressure,
61 double baseline_discharge_pressure,
62 double modified_discharge_pressure,
63 double altitude_pressure = 14.69,
64 double atmospheric_pressure = 14.69);
65
66double adjustedPower(double rated_full_load_power, double rated_full_load_pressure, double discharge_pressure,
67 double altitude_pressure = 14.69, double atmospheric_pressure = 14.69);
68
69} // namespace compressed_air::assessment::compressor_eem
double adjustedUseAirflowAcfm