MEASUR-Tools-Suite v1.2.4
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
Compressor model result for blow-off controls. More...
#include <compressor.h>
Public Attributes | |
| double | powerKw = 0.0 |
| Calculated compressor package power \([\unit{\kilo\watt}]\). | |
| double | airflowAcfm = 0.0 |
| Calculated useful compressor airflow \([\unit{\acfm}]\). | |
| double | powerFraction = 0.0 |
| Calculated fraction of full-load power \([\unit{\unitless}]\). | |
| double | airflowFraction = 0.0 |
| Calculated fraction of full-load useful airflow \([\unit{\unitless}]\). | |
| double | blowOffAirflowAcfm = 0.0 |
| Calculated blow-off airflow \([\unit{\acfm}]\). | |
| double | blowOffFraction = 0.0 |
| Calculated fraction of full-load airflow blown off \([\unit{\unitless}]\). | |
Definition at line 93 of file compressor.h.
| double compressed_air::assessment::CompressorBlowOffResult::airflowAcfm = 0.0 |
Definition at line 95 of file compressor.h.
| double compressed_air::assessment::CompressorBlowOffResult::airflowFraction = 0.0 |
Definition at line 97 of file compressor.h.
| double compressed_air::assessment::CompressorBlowOffResult::blowOffAirflowAcfm = 0.0 |
Definition at line 98 of file compressor.h.
| double compressed_air::assessment::CompressorBlowOffResult::blowOffFraction = 0.0 |
Definition at line 99 of file compressor.h.
| double compressed_air::assessment::CompressorBlowOffResult::powerFraction = 0.0 |
Definition at line 96 of file compressor.h.
| double compressed_air::assessment::CompressorBlowOffResult::powerKw = 0.0 |
Definition at line 94 of file compressor.h.