air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults Struct Reference

Results of the air/water cooling using flue calculation. More...

#include <air_water_cooling_using_flue.h>

Public Attributes

double excess_air = 0
 Excess air fraction \([\unit{\unitless}]\).
 
double flow_flue_gas = 0
 Flue gas flow \([\unit{\pound\per\hour}]\).
 
double specific_heat = 0
 Specific heat \([\unit{\btu\per\pound\degreeFahrenheit}]\).
 
double fraction_condensed = 0
 Fraction of water vapor condensed \([\unit{\unitless}]\).
 
double available_heat_fraction = 0
 Fraction of heat available (sensible only) \([\unit{\unitless}]\).
 
double total_available_heat_fraction = 0
 Fraction of heat available (sensible + latent) \([\unit{\unitless}]\).
 
double latent_heat_fraction = 0
 Fraction of heat available due to latent heat \([\unit{\unitless}]\).
 
double latent_heat_recovery = 0
 Latent heat recovered \([\unit{\mega\btu\per\hour}]\).
 
double sensible_heat_recovery = 0
 Sensible heat recovered \([\unit{\mega\btu\per\hour}]\).
 

Detailed Description

Contains all output values from the air/water cooling using flue calculation.

Definition at line 24 of file air_water_cooling_using_flue.h.

Member Data Documentation

◆ available_heat_fraction

double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::available_heat_fraction = 0

Definition at line 29 of file air_water_cooling_using_flue.h.

◆ excess_air

double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::excess_air = 0

Definition at line 25 of file air_water_cooling_using_flue.h.

◆ flow_flue_gas

double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::flow_flue_gas = 0

Definition at line 26 of file air_water_cooling_using_flue.h.

◆ fraction_condensed

double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::fraction_condensed = 0

Definition at line 28 of file air_water_cooling_using_flue.h.

◆ latent_heat_fraction

double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::latent_heat_fraction = 0

Definition at line 31 of file air_water_cooling_using_flue.h.

◆ latent_heat_recovery

double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::latent_heat_recovery = 0

Definition at line 32 of file air_water_cooling_using_flue.h.

◆ sensible_heat_recovery

double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::sensible_heat_recovery = 0

Definition at line 33 of file air_water_cooling_using_flue.h.

◆ specific_heat

double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::specific_heat = 0

Definition at line 27 of file air_water_cooling_using_flue.h.

◆ total_available_heat_fraction

double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::total_available_heat_fraction = 0

Definition at line 30 of file air_water_cooling_using_flue.h.