MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
Results of the air/water cooling using flue calculation. More...
#include <air_water_cooling_using_flue.h>
Public Attributes | |
| double | excess_air = 0 |
| Excess air fraction \([\unit{\unitless}]\). | |
| double | flow_flue_gas = 0 |
| Flue gas flow \([\unit{\pound\per\hour}]\). | |
| double | specific_heat = 0 |
| Specific heat \([\unit{\btu\per\pound\degreeFahrenheit}]\). | |
| double | fraction_condensed = 0 |
| Fraction of water vapor condensed \([\unit{\unitless}]\). | |
| double | available_heat_fraction = 0 |
| Fraction of heat available (sensible only) \([\unit{\unitless}]\). | |
| double | total_available_heat_fraction = 0 |
| Fraction of heat available (sensible + latent) \([\unit{\unitless}]\). | |
| double | latent_heat_fraction = 0 |
| Fraction of heat available due to latent heat \([\unit{\unitless}]\). | |
| double | latent_heat_recovery = 0 |
| Latent heat recovered \([\unit{\mega\btu\per\hour}]\). | |
| double | sensible_heat_recovery = 0 |
| Sensible heat recovered \([\unit{\mega\btu\per\hour}]\). | |
Contains all output values from the air/water cooling using flue calculation.
Definition at line 24 of file air_water_cooling_using_flue.h.
| double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::available_heat_fraction = 0 |
Definition at line 29 of file air_water_cooling_using_flue.h.
| double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::excess_air = 0 |
Definition at line 25 of file air_water_cooling_using_flue.h.
| double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::flow_flue_gas = 0 |
Definition at line 26 of file air_water_cooling_using_flue.h.
| double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::fraction_condensed = 0 |
Definition at line 28 of file air_water_cooling_using_flue.h.
| double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::latent_heat_fraction = 0 |
Definition at line 31 of file air_water_cooling_using_flue.h.
| double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::latent_heat_recovery = 0 |
Definition at line 32 of file air_water_cooling_using_flue.h.
| double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::sensible_heat_recovery = 0 |
Definition at line 33 of file air_water_cooling_using_flue.h.
| double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::specific_heat = 0 |
Definition at line 27 of file air_water_cooling_using_flue.h.
| double air_water_cooling_using_flue::AirWaterCoolingUsingFlueResults::total_available_heat_fraction = 0 |
Definition at line 30 of file air_water_cooling_using_flue.h.