MEASUR-Tools-Suite v1.2.6
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
Loading...
Searching...
No Matches
Classes | Namespaces | Functions

Declares calculations of the pump head developed from measured operating conditions. More...

Go to the source code of this file.

Classes

struct  pump_head::SuctionGaugeInput
 Inputs for a pump system whose suction condition is measured by a gauge. More...
 
struct  pump_head::SuctionTankInput
 Inputs for a pump system supplied from a pressurized suction tank. More...
 
struct  pump_head::Result
 Component heads and pump head. More...
 

Namespaces

namespace  pump_head
 Calculates pump head from measured system operating conditions.
 

Functions

Result pump_head::calculateFromSuctionGauge (const SuctionGaugeInput &input)
 Calculates pump head from suction- and discharge-gauge measurements.
 
Result pump_head::calculateFromSuctionTank (const SuctionTankInput &input)
 Calculates pump head for a system supplied from a pressurized suction tank.
 

Detailed Description

The calculation resolves pump head into elevation, pressure, velocity, and estimated suction- and discharge-line friction components. Suction conditions may be defined by either a pressure gauge or a pressurized tank. Gauge elevations are measured at the centers of the gauges from a common datum and must correspond to the supplied pressure readings. If a reading is corrected to another reference elevation, use that elevation instead.

See also
Pump Head Calculator for formula derivations, units, and assumptions.

Definition in file pump_head.h.