MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
Declarations for compressed air pipe sizing calculations. More...
Go to the source code of this file.
Classes | |
| struct | pipe_sizing::Input |
| Input parameters for the pipe sizing calculation. More... | |
| struct | pipe_sizing::Result |
| Result of the pipe sizing calculation. More... | |
Namespaces | |
| namespace | pipe_sizing |
| Compressed air pipe sizing calculator. | |
Functions | |
| Result | pipe_sizing::calculate (const Input &input) |
| Calculates the minimum pipe cross-sectional area and diameter for a compressed air system. | |
Variables | |
| constexpr double | pipe_sizing::kCircleAreaFactor = 0.78 |
| Industry-standard approximation of \(\pi / 4\) used in pipe diameter calculations. | |
Provides a function to determine the required cross-sectional area and minimum internal diameter of a compressed air distribution pipe given the volumetric flow rate, operating pressure, and design velocity. All calculations use U.S. customary units.
Definition in file pipe_sizing.h.