MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
Loading...
Searching...
No Matches
Namespaces | Functions

Go to the source code of this file.

Namespaces

namespace  opening_heat_loss
 Calculates heat losses from process heating equipment openings to the ambient.
 

Functions

double opening_heat_loss::totalHeatLoss (double area, double emissivity, double insideTemperature, double ambientTemperature, double viewFactor, double percentTimeOpen)
 Calculates the total heat loss for a process heating equipment opening with a given area.
 
double opening_heat_loss::totalHeatLossQuad (double emissivity, double length, double width, double ambientTemperature, double insideTemperature, double percentTimeOpen, double viewFactor)
 Calculates total heat loss for a rectangular opening.
 
double opening_heat_loss::totalHeatLossCircular (double emissivity, double diameter, double ambientTemperature, double insideTemperature, double percentTimeOpen, double viewFactor)
 Calculates total heat loss for a circlular opening.
 
double opening_heat_loss::calculateViewFactorCircular (double thickness, double diameter)
 Calculates the view factor for a circular opening.
 
double opening_heat_loss::calculateViewFactorQuad (double thickness, double length, double height)
 Calculates the view factor for a rectangular opening.
 

Detailed Description

Authors
Gina Accawi, Mark Root

Calculates heat losses from process heating equipment openings to the ambient.

Definition in file opening_heat_loss.h.