MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
Efficiency improvement calculations for process heating systems.
Classes | |
| struct | ProcessHeatEfficiencyImprovementResults |
| Results of the process heat efficiency improvement calculation. More... | |
Functions | |
| ProcessHeatEfficiencyImprovementResults | processHeatEfficiencyImprovement (double current_flue_gas_oxygen, double new_flue_gas_oxygen, double current_flue_gas_temp, double new_flue_gas_temp, double current_combustion_air_temp, double new_combustion_air_temp, double current_energy_input) |
| Calculates the efficiency improvement for a fuel fired furnace. | |
| double | calculateExcessAir (double flue_gas_oxygen, double stoich_air_multiplier, double excess_air_denominator_base, double excess_air_o2_multiplier) |
| Calculates excess air percentage. | |
| double | calculateHeatInput (double flue_gas_temp, double heat_input_base, double heat_input_temp_coeff) |
| Calculates heat input. | |
| double | calculateAirSpecificHeat (double combustion_air_temp, double air_specific_heat_base, double air_specific_heat_coeff) |
| Calculates air specific heat. | |
| double | calculateAirCorrection (double air_correction_base, double air_specific_heat, double flue_gas_temp, double excess_air) |
| Calculates air correction. | |
| double | calculateCombustionAirCorrection (double combustion_air_correction_base, double air_specific_heat, double combustion_air_temp, double excess_air) |
| Calculates combustion air correction. | |
| double | calculateAvailableHeat (double heat_input, double air_correction, double combustion_air_correction) |
| Calculates available heat. | |
| double | calculateFuelSavings (double new_available_heat, double current_available_heat) |
| Calculates new fuel savings. | |
| double | calculateNewEnergyInput (double current_energy_input, double new_fuel_savings) |
| Calculates new energy input. | |