MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
Compressed air leak estimation using visual and audible assessment. More...
Classes | |
| struct | Input |
| Input parameters for the estimate method compressed air leak calculation. More... | |
| struct | Result |
| Result of the estimate method leak annual consumption calculation. More... | |
Functions | |
| Result | calculate (const Input &input) |
| Estimates annual compressed air consumption from a leak using the estimate method. | |
The estimate method provides a rapid field assessment of compressed air leak severity. An operator categorizes a leak by audible and visual clues (e.g., hissing sound, visible moisture or contamination) and assigns a corresponding estimated flow rate. That rate is then multiplied by annual operating time to yield the projected annual air loss. This approach trades precision for speed and is most appropriate for initial leak surveys, after which higher-accuracy methods such as the bag method or orifice method can be used for significant leaks.
Annual consumption is the product of the estimated leak rate, annual operating time, and the minutes-per-hour conversion factor, then divided by the scf-to-kscf factor.
Annual Consumption:
\begin{equation}\label{eq:estimate-method-annual-consumption} C_{annual} = \frac{\dot{Q}_{leak} \cdot t_{op} \cdot 60}{1000} \end{equation}
where:
| \(C_{annual}\) | Estimated annual air loss from the leak \([\unit{ \kscf}]\) |
| \(\dot{Q}_{leak}\) | Estimated compressed air leak flow rate \([\unit{ \scfm}]\) |
| \(t_{op}\) | Annual system operating time \([\unit{ \hour}]\) |
| \(60\) | Minutes per hour conversion \([\unit{ \minute\per\hour}]\) |
| \(1000\) | Standard cubic feet per kiloscf conversion \([\unit{ \unitless}]\) |
| [in] | input | Input |
annual_consumption [kscf].