MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
This database provides default values for shape factors associated with various wall types. The data is used in wall heat loss calculations for process heating systems.
The following table lists the default wall types and their shape factor values:
| Wall Description | Shape Factor \([\unit{\unitless}]\) |
|---|---|
| Horizontal cylinders | 1.016 |
| Longer vertical cylinders | 1.235 |
| Vertical plates | 1.394 |
| Horizontal plate facing up, warmer than air | 1.79 |
| Horizontal plate facing down, warmer than air | 0.89 |
| Horizontal plate facing up, cooler than air | 0.89 |
| Horizontal plate facing down, cooler than air | 1.79 |
Modules | |
| Default Wall Type Data | |