MEASUR-Tools-Suite v1.2.4
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
The length constructor multiplies each entered pipe length by a per-foot volume coefficient for that nominal pipe size.
\begin{equation}\label{eq:pipe-data-volume} V_i = L_i \cdot c_i \end{equation}
| \(V_i\) | Contained pipe volume for nominal size i \([\unit{ \cubicFoot}]\) |
| \(L_i\) | Installed pipe length for nominal size i \([\unit{ \foot}]\) |
| \(c_i\) | Pipe volume coefficient for nominal size i \([\unit{ \cubicFoot\per\foot}]\) |