The volume coefficients are used by the length constructor. The internal areas are passed to the air velocity formula. The existing source does not identify the external standard behind these values, so they are documented here as implementation tables.
| Nominal pipe size | Volume coefficient \([\unit{\cubicFoot\per\foot}]\) | Internal area \([\unit{\inch\squared}]\) |
|---|---|---|
| 1/2 in | 0.0021 | 0.3 |
| 3/4 in | 0.0037 | 0.53 |
| 1 in | 0.006 | 0.86 |
| 1-1/4 in | 0.0104 | 1.5 |
| 1-1/2 in | 0.0141 | 2.04 |
| 2 in | 0.0233 | 3.36 |
| 2-1/2 in | 0.0333 | 4.79 |
| 3 in | 0.0513 | 7.39 |
| 3-1/2 in | 0.0687 | 9.89 |
| 4 in | 0.0884 | 12.73 |
| 5 in | 0.1389 | 20 |
| 6 in | 0.2006 | 28.89 |
| 8 in | 0.3442 | 50.02 |
| 10 in | 0.5476 | 78.85 |
| 12 in | 0.7763 | 111.9 |
| 14 in | 0.9354 | 135.3 |
| 16 in | 1.223 | 176.7 |
| 18 in | 1.555 | 224 |
| 20 in | 1.926 | 278 |
| 24 in | 2.793 | 402.10 |