MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
\begin{equation}\label{eq:liquid-load-charge-material-total-heat-required-cpp} Q_{total} = Q_{liq} + Q_{reaction} + Q_{additional}\end{equation}
| \(Q_{total}\) | Total heat required \([\unit{ \btu\per\hour}]\) |
| \(Q_{liq}\) | Heat required for liquid heating/vaporization \([\unit{ \btu\per\hour}]\) |
| \(Q_{reaction}\) | Heat of reaction \([\unit{ \btu\per\hour}]\) |
| \(Q_{additional}\) | Additional heat required \([\unit{ \btu\per\hour}]\) |