MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
Loading...
Searching...
No Matches
Modules
Gas Type Database

Detailed Description

This database provides default values for the specific heat of common atmospheric gases at a reference temperature of \(\qty{60}{\degreeFahrenheit}\). The data is used in atmosphere heat loss calculations for process heating systems.

Default Gas Type Data


The following table lists the default gas types and their specific heat values:

Gas Description Specific Heat \([\unit{\btu\per\standardCubicFeet\degreeFahrenheit}]\)
Nitrogen 0.0185
Hydrogen 0.0182
Exothermic Gas 0.0185
Endothermic Gas 0.0185
Air 0.0184
Water Vapor 0.0212
Note
Values are at a reference temperature of \(\qty{60}{\degreeFahrenheit}\) and may vary with pressure and temperature.
See also
Atmosphere Heat Loss Calculator

Modules