MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
The total energy savings is calculated by multiplying the hourly energy savings by the effective operating hours.
\begin{equation}\label{eq:cascade-high-to-low-total-energy-savings} E_{savings} = E_{hourly} \cdot H_{eff}\end{equation}
| \(E_{savings}\) | Total energy savings \([\unit{ \MMBtu\per\year}]\) |
| \(E_{hourly}\) | Hourly energy savings \([\unit{ \MMBtu\per\hour}]\) |
| \(H_{eff}\) | Effective operating hours \([\unit{ \hour\per\year}]\) |