MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
The hourly energy savings is the minimum of the equivalent energy supply and the low-temperature process firing rate.
\begin{equation}\label{eq:cascade-high-to-low-hourly-energy-savings} E_{hourly} = \min(E_{supply}, F_{low})\end{equation}
| \(E_{hourly}\) | Hourly energy savings \([\unit{ \MMBtu\per\hour}]\) |
| \(E_{supply}\) | Equivalent energy supply \([\unit{ \MMBtu\per\hour}]\) |
| \(F_{low}\) | Low-temperature process firing rate \([\unit{ \MMBtu\per\hour}]\) |