MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
Loading...
Searching...
No Matches

The equivalent energy supply is calculated by dividing the heat exchanger energy rate by the available heat of the low-temperature process.

\begin{equation}\label{eq:cascade-high-to-low-eq-energy-supply} E_{supply} = \frac{Q_{hx}}{AH_{low}}\end{equation}

Symbols
\(E_{supply}\)Equivalent energy supply \([\unit{ \MMBtu\per\hour}]\)
\(Q_{hx}\)Heat exchanger energy rate \([\unit{ \MMBtu\per\hour}]\)
\(AH_{low}\)Available heat of low-temp process \([\unit{ \unitless}]\)