MEASUR-Tools-Suite v1.0.11
The MEASUR Tools Suite is a collection of industrial efficiency calculations written in C++ and with bindings for compilation to WebAssembly.
|
Go to the source code of this file.
Classes | |
| struct | energy_input_exhaust_gas_heat_loss::EnergyInputExhaustGasResult |
| Result struct for energy input exhaust gas heat loss calculations. More... | |
Namespaces | |
| namespace | energy_input_exhaust_gas_heat_loss |
| Calculates available heat, heat delivered, and exhaust gas losses for non-EAF electric furnaces. | |
Functions | |
| double | energy_input_exhaust_gas_heat_loss::availableHeat (double excess_air, double combustion_air_temp, double exhaust_gas_temp, double total_heat_input=1) |
| Calculates available heat for a non-EAF electric furnace. | |
| double | energy_input_exhaust_gas_heat_loss::heatDelivered (double available_heat, double total_heat_input) |
| Calculates heat delivered for a non-EAF electric furnace. | |
| double | energy_input_exhaust_gas_heat_loss::totalHeatLoss (double heat_delivered, double available_heat) |
| Calculates exhaust gas losses for a non-EAF electric furnace. | |
| EnergyInputExhaustGasResult | energy_input_exhaust_gas_heat_loss::calculate (double excess_air, double combustion_air_temp, double exhaust_gas_temp, double total_heat_input=1) |
| Calculates available heat, heat delivered, and exhaust gas losses for a non-EAF electric furnace. | |
Calculates available heat, heat delivered, and exhaust gas losses for non-EAF electric furnaces.
Definition in file energy_input_exhaust_gas_heat_loss.h.