compressed_air::assessment::VariableFrequencyDriveCompressor Class Reference

Compressor model for variable frequency drive control. More...

#include <vfd_compressor.h>

Inheritance diagram for compressed_air::assessment::VariableFrequencyDriveCompressor:
compressed_air::assessment::CompressorModelBase

Public Member Functions

 VariableFrequencyDriveCompressor (double full_load_power, double mid_turndown_power, double turndown_power, double no_load_power, double full_load_airflow, double mid_turndown_airflow, double turndown_airflow)
 
CompressorPerformanceResult calculateFromPowerFraction (double power_fraction)
 
CompressorPerformanceResult calculateFromCapacityFraction (double airflow_fraction)
 
CompressorPerformanceResult calculateFromMeasuredPower (double power)
 
CompressorPerformanceResult calculateFromMeasuredCapacity (double airflow)
 
CompressorPerformanceResult calculateFromElectrical (double voltage, double current, double power_factor)
 
- Public Member Functions inherited from compressed_air::assessment::CompressorModelBase
double adjustedFullLoadPowerKw () const
 
double adjustedFullLoadAirflowAcfm () const
 
double adjustedMaxPowerKw () const
 
double adjustedMaxAirflowAcfm () const
 

Private Attributes

double turndown_power_fraction_
 
double no_load_power_fraction_
 
double mid_turndown_power_fraction_
 
double turndown_airflow_fraction_
 
double mid_turndown_airflow_fraction_
 
double no_load_power_
 

Additional Inherited Members

- Protected Member Functions inherited from compressed_air::assessment::CompressorModelBase
 CompressorModelBase (double full_load_power, double full_load_airflow)
 
void applyPressureInletCorrection (CompressorType compressor_type, double capacity, double full_load_bhp, double poly_exponent, double rated_discharge_pressure, double rated_inlet_pressure, double efficiency, double full_load_pressure, double max_pressure, double inlet_pressure, bool pressure_adjustment, double atmospheric_pressure)
 
- Static Protected Member Functions inherited from compressed_air::assessment::CompressorModelBase
static double roundDouble (double value)
 
- Protected Attributes inherited from compressed_air::assessment::CompressorModelBase
double full_load_power_
 
double full_load_airflow_
 
const double full_load_airflow_raw_
 
const double full_load_power_raw_
 
double full_load_power_adjusted_
 
double full_load_airflow_adjusted_
 
double max_airflow_adjusted_
 
double max_power_adjusted_
 

Detailed Description

Definition at line 17 of file vfd_compressor.h.

Member Data Documentation

◆ mid_turndown_airflow_fraction_

double compressed_air::assessment::VariableFrequencyDriveCompressor::mid_turndown_airflow_fraction_
private

Definition at line 34 of file vfd_compressor.h.

◆ mid_turndown_power_fraction_

double compressed_air::assessment::VariableFrequencyDriveCompressor::mid_turndown_power_fraction_
private

Definition at line 32 of file vfd_compressor.h.

◆ no_load_power_

double compressed_air::assessment::VariableFrequencyDriveCompressor::no_load_power_
private

Definition at line 35 of file vfd_compressor.h.

◆ no_load_power_fraction_

double compressed_air::assessment::VariableFrequencyDriveCompressor::no_load_power_fraction_
private

Definition at line 31 of file vfd_compressor.h.

◆ turndown_airflow_fraction_

double compressed_air::assessment::VariableFrequencyDriveCompressor::turndown_airflow_fraction_
private

Definition at line 33 of file vfd_compressor.h.

◆ turndown_power_fraction_

double compressed_air::assessment::VariableFrequencyDriveCompressor::turndown_power_fraction_
private

Definition at line 30 of file vfd_compressor.h.


The documentation for this class was generated from the following file: