Centrifugal compressor model with blow-off control.
More...
#include <centrifugal_compressor.h>
|
|
| CentrifugalBlowOffCompressor (double full_load_power, double full_load_airflow, double blow_off_power, double blow_off_airflow) |
| |
|
CompressorBlowOffResult | calculateFromPowerFraction (double power_fraction, double blow_off_fraction) |
| |
|
CompressorBlowOffResult | calculateFromCapacityFraction (double airflow_fraction) |
| |
|
CompressorBlowOffResult | calculateFromMeasuredPower (double power, double blow_off_fraction) |
| |
|
CompressorBlowOffResult | calculateFromMeasuredCapacity (double airflow) |
| |
|
CompressorBlowOffResult | calculateFromElectrical (double voltage, double current, double power_factor, double blow_off_fraction) |
| |
|
void | adjustDischargePressure (const std::vector< double > &capacity, const std::vector< double > &discharge_pressure, double full_load_pressure, double max_pressure=0.0) |
| |
| double | adjustedFullLoadPowerKw () const |
| |
| double | adjustedFullLoadAirflowAcfm () const |
| |
| double | adjustedMaxPowerKw () const |
| |
| double | adjustedMaxAirflowAcfm () const |
| |
|
| | CompressorModelBase (double full_load_power, double full_load_airflow) |
| |
|
void | applyPressureInletCorrection (CompressorType compressor_type, double capacity, double full_load_bhp, double poly_exponent, double rated_discharge_pressure, double rated_inlet_pressure, double efficiency, double full_load_pressure, double max_pressure, double inlet_pressure, bool pressure_adjustment, double atmospheric_pressure) |
| |
|
static double | roundDouble (double value) |
| |
| double | full_load_power_ |
| |
| double | full_load_airflow_ |
| |
| const double | full_load_airflow_raw_ |
| |
| const double | full_load_power_raw_ |
| |
| double | full_load_power_adjusted_ |
| |
| double | full_load_airflow_adjusted_ |
| |
| double | max_airflow_adjusted_ |
| |
| double | max_power_adjusted_ |
| |
Definition at line 19 of file centrifugal_compressor.h.
◆ blow_off_airflow_
| double compressed_air::assessment::CentrifugalBlowOffCompressor::blow_off_airflow_ = 1.0 |
|
private |
◆ blow_off_airflow_fraction_
| double compressed_air::assessment::CentrifugalBlowOffCompressor::blow_off_airflow_fraction_ = 1.0 |
|
private |
◆ blow_off_power_fraction_
| double compressed_air::assessment::CentrifugalBlowOffCompressor::blow_off_power_fraction_ = 0.0 |
|
private |
The documentation for this class was generated from the following file: