#include <EnergyEquivalency.h>
Fuel Fired Energy Equivalency calculator class Used to calculateThermalResistance the fuel-fired heat input that is equivalent to the electric heat input.
Definition at line 110 of file EnergyEquivalency.h.
◆ FuelFiredEnergyEquivalency()
FuelFiredEnergyEquivalency::FuelFiredEnergyEquivalency |
( |
double |
electricallyHeatedEfficiency, |
|
|
double |
fuelFiredEfficiency, |
|
|
double |
electricalHeatInput |
|
) |
| |
|
inline |
Constructor for the fuel-fired equivalency calculator
- Parameters
-
electricallyHeatedEfficiency | double, electrically heated equipment efficiency as % |
fuelFiredEfficiency | double, fuel-fired equipment efficiency as % |
electricalHeatInput | double, heat input for electrically heated equipment in kW |
Definition at line 122 of file EnergyEquivalency.h.
◆ getElectricalHeatInput()
double FuelFiredEnergyEquivalency::getElectricalHeatInput |
( |
| ) |
const |
|
inline |
Getter for the heat input for electrically heated equipment
- Returns
- double, heat input for electrically heated equipment in kW
Definition at line 170 of file EnergyEquivalency.h.
◆ getElectricallyHeatedEfficiency()
double FuelFiredEnergyEquivalency::getElectricallyHeatedEfficiency |
( |
| ) |
const |
|
inline |
Getter for the electrically heated equipment efficiency
- Returns
- double, electrically heated equipment efficiency as %
Definition at line 138 of file EnergyEquivalency.h.
◆ getFuelFiredEfficiency()
double FuelFiredEnergyEquivalency::getFuelFiredEfficiency |
( |
| ) |
const |
|
inline |
Getter for the fuel-fired equipment efficiency
- Returns
- double, fuel-fired equipment efficiency as %
Definition at line 155 of file EnergyEquivalency.h.
◆ getFuelFiredHeatInput()
double FuelFiredEnergyEquivalency::getFuelFiredHeatInput |
( |
| ) |
|
Gets the equivalent fuel-fired heat input
- Returns
- double, equivalent fuel-fired heat input in MM Btu/hr
◆ setElectricalHeatInput()
void FuelFiredEnergyEquivalency::setElectricalHeatInput |
( |
double |
electricalHeatInput | ) |
|
|
inline |
Sets the heat input for electrically heated equipment
- Parameters
-
electricalHeatInput | double, heat input for electrically heated equipment in kW |
Definition at line 178 of file EnergyEquivalency.h.
◆ setElectricallyHeatedEfficiency()
void FuelFiredEnergyEquivalency::setElectricallyHeatedEfficiency |
( |
double |
electricallyHeatedEfficiency | ) |
|
|
inline |
Sets the electrically heated equipment efficiency
- Parameters
-
electricallyHeatedEfficiency | double, electrically heated equipment efficiency as % |
Definition at line 146 of file EnergyEquivalency.h.
◆ setFuelFiredEfficiency()
void FuelFiredEnergyEquivalency::setFuelFiredEfficiency |
( |
double |
fuelFiredEfficiency | ) |
|
|
inline |
Sets the fuel-fired equipment efficiency
- Parameters
-
fuelFiredEfficiency | double, fuel-fired equipment efficiency as % |
Definition at line 163 of file EnergyEquivalency.h.
◆ electricalHeatInput_
double FuelFiredEnergyEquivalency::electricalHeatInput_ = 0.0 |
|
private |
◆ electricallyHeatedEfficiency_
double FuelFiredEnergyEquivalency::electricallyHeatedEfficiency_ = 0.0 |
|
private |
◆ fuelFiredEfficiency_
double FuelFiredEnergyEquivalency::fuelFiredEfficiency_ = 0.0 |
|
private |
◆ fuelFiredHeatInput_
double FuelFiredEnergyEquivalency::fuelFiredHeatInput_ |
|
private |